Can a relay be on for 16 hours continuously? The 2019 Stack Overflow Developer Survey Results Are In Announcing the arrival of Valued Associate #679: Cesar Manara Planned maintenance scheduled April 17/18, 2019 at 00:00UTC (8:00pm US/Eastern) Congratulation Joan for 50k!16 channel relay for RPiSimple Relay ControlWhat things I can use for turning on a relay?3V3 enough for a 5V relay?Relay boards that can handle 20V 20A DCCircuit complete near high voltage machineComponents for relay setup with Raspberry PiRaspi's USB and Ethernet occasionally shut down when connecting relay boardOpen/Close Sliding Gate Using Raspberry Pi and PythonDetecting electricity via a relay board

Do working physicists consider Newtonian mechanics to be "falsified"?

What are these Gizmos at Izaña Atmospheric Research Center in Spain?

How can I protect witches in combat who wear limited clothing?

Why did all the guest students take carriages to the Yule Ball?

Is it ok to offer lower paid work as a trial period before negotiating for a full-time job?

What's the point in a preamp?

What aspect of planet Earth must be changed to prevent the industrial revolution?

Why can't devices on different VLANs, but on the same subnet, communicate?

Can withdrawing asylum be illegal?

Why does the Event Horizon Telescope (EHT) not include telescopes from Africa, Asia or Australia?

Wall plug outlet change

Are spiders unable to hurt humans, especially very small spiders?

In horse breeding, what is the female equivalent of putting a horse out "to stud"?

Can a novice safely splice in wire to lengthen 5V charging cable?

Derivation tree not rendering

What information about me do stores get via my credit card?

Semisimplicity of the category of coherent sheaves?

system() function string length limit

Create an outline of font

How does this infinite series simplify to an integral?

How is simplicity better than precision and clarity in prose?

How to copy the contents of all files with a certain name into a new file?

How to remove this toilet supply line that seems to have no nut?

What is this lever in Argentinian toilets?



Can a relay be on for 16 hours continuously?



The 2019 Stack Overflow Developer Survey Results Are In
Announcing the arrival of Valued Associate #679: Cesar Manara
Planned maintenance scheduled April 17/18, 2019 at 00:00UTC (8:00pm US/Eastern)
Congratulation Joan for 50k!16 channel relay for RPiSimple Relay ControlWhat things I can use for turning on a relay?3V3 enough for a 5V relay?Relay boards that can handle 20V 20A DCCircuit complete near high voltage machineComponents for relay setup with Raspberry PiRaspi's USB and Ethernet occasionally shut down when connecting relay boardOpen/Close Sliding Gate Using Raspberry Pi and PythonDetecting electricity via a relay board



.everyoneloves__top-leaderboard:empty,.everyoneloves__mid-leaderboard:empty,.everyoneloves__bot-mid-leaderboard:empty margin-bottom:0;








1















A part of my engineering project involves a L.E.D tubelight staying on for 16 hours continuously. I am connecting the light to a relay module. Is it ok, if the relay stays on for so long? I mean, is it designed to sustain for such a huge period of time?










share|improve this question




























    1















    A part of my engineering project involves a L.E.D tubelight staying on for 16 hours continuously. I am connecting the light to a relay module. Is it ok, if the relay stays on for so long? I mean, is it designed to sustain for such a huge period of time?










    share|improve this question
























      1












      1








      1








      A part of my engineering project involves a L.E.D tubelight staying on for 16 hours continuously. I am connecting the light to a relay module. Is it ok, if the relay stays on for so long? I mean, is it designed to sustain for such a huge period of time?










      share|improve this question














      A part of my engineering project involves a L.E.D tubelight staying on for 16 hours continuously. I am connecting the light to a relay module. Is it ok, if the relay stays on for so long? I mean, is it designed to sustain for such a huge period of time?







      electronics relay






      share|improve this question













      share|improve this question











      share|improve this question




      share|improve this question










      asked 12 hours ago









      Aditya RaghuAditya Raghu

      142




      142




















          2 Answers
          2






          active

          oldest

          votes


















          3














          The first stop to answer such questions should be the datasheet of the part in question. This is where the manufacturer lists the operating conditions of the device.



          That aside it is usually safe to have a relay active for longer periods of time, assuming you're within the operational range of current and voltage (again, as laid out in the datasheet).



          Wear and tear of an electromechanical relay is usually due to switching under load, i.e. with a voltage applied to the terminals, not being permanently on or off. For more on the issue of contact degradation see here https://en.wikipedia.org/wiki/Relay#Arcing (which I won't make part of this answer as it does not address the question).






          share|improve this answer























          • Thank you so much for your help @Ghanima. Btw does a timer relay also have the same working?

            – Aditya Raghu
            11 hours ago


















          1














          To add to @Ghanima's excellent answer, you may also wish to consider a latching relay. Briefly, a latching relay has two stable states (i.e. it is a bistable device, similar to a flip-flop). This means that the relay can be latched into an OPEN or CLOSED state, and it will remain in that state until commanded to change by the input. This avoids the necessity of supplying input voltage and current to maintain (for example) a NORMALLY OPEN relay in a CLOSED state for an extended period of time. Latching relays typically find application in situations similar to the one you've described in your question - where they must be in an OPEN or CLOSED state for extended periods of time.






          share|improve this answer























            Your Answer






            StackExchange.ifUsing("editor", function ()
            return StackExchange.using("schematics", function ()
            StackExchange.schematics.init();
            );
            , "cicuitlab");

            StackExchange.ready(function()
            var channelOptions =
            tags: "".split(" "),
            id: "447"
            ;
            initTagRenderer("".split(" "), "".split(" "), channelOptions);

            StackExchange.using("externalEditor", function()
            // Have to fire editor after snippets, if snippets enabled
            if (StackExchange.settings.snippets.snippetsEnabled)
            StackExchange.using("snippets", function()
            createEditor();
            );

            else
            createEditor();

            );

            function createEditor()
            StackExchange.prepareEditor(
            heartbeatType: 'answer',
            autoActivateHeartbeat: false,
            convertImagesToLinks: false,
            noModals: true,
            showLowRepImageUploadWarning: true,
            reputationToPostImages: null,
            bindNavPrevention: true,
            postfix: "",
            imageUploader:
            brandingHtml: "Powered by u003ca class="icon-imgur-white" href="https://imgur.com/"u003eu003c/au003e",
            contentPolicyHtml: "User contributions licensed under u003ca href="https://creativecommons.org/licenses/by-sa/3.0/"u003ecc by-sa 3.0 with attribution requiredu003c/au003e u003ca href="https://stackoverflow.com/legal/content-policy"u003e(content policy)u003c/au003e",
            allowUrls: true
            ,
            onDemand: true,
            discardSelector: ".discard-answer"
            ,immediatelyShowMarkdownHelp:true
            );



            );













            draft saved

            draft discarded


















            StackExchange.ready(
            function ()
            StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fraspberrypi.stackexchange.com%2fquestions%2f96471%2fcan-a-relay-be-on-for-16-hours-continuously%23new-answer', 'question_page');

            );

            Post as a guest















            Required, but never shown

























            2 Answers
            2






            active

            oldest

            votes








            2 Answers
            2






            active

            oldest

            votes









            active

            oldest

            votes






            active

            oldest

            votes









            3














            The first stop to answer such questions should be the datasheet of the part in question. This is where the manufacturer lists the operating conditions of the device.



            That aside it is usually safe to have a relay active for longer periods of time, assuming you're within the operational range of current and voltage (again, as laid out in the datasheet).



            Wear and tear of an electromechanical relay is usually due to switching under load, i.e. with a voltage applied to the terminals, not being permanently on or off. For more on the issue of contact degradation see here https://en.wikipedia.org/wiki/Relay#Arcing (which I won't make part of this answer as it does not address the question).






            share|improve this answer























            • Thank you so much for your help @Ghanima. Btw does a timer relay also have the same working?

              – Aditya Raghu
              11 hours ago















            3














            The first stop to answer such questions should be the datasheet of the part in question. This is where the manufacturer lists the operating conditions of the device.



            That aside it is usually safe to have a relay active for longer periods of time, assuming you're within the operational range of current and voltage (again, as laid out in the datasheet).



            Wear and tear of an electromechanical relay is usually due to switching under load, i.e. with a voltage applied to the terminals, not being permanently on or off. For more on the issue of contact degradation see here https://en.wikipedia.org/wiki/Relay#Arcing (which I won't make part of this answer as it does not address the question).






            share|improve this answer























            • Thank you so much for your help @Ghanima. Btw does a timer relay also have the same working?

              – Aditya Raghu
              11 hours ago













            3












            3








            3







            The first stop to answer such questions should be the datasheet of the part in question. This is where the manufacturer lists the operating conditions of the device.



            That aside it is usually safe to have a relay active for longer periods of time, assuming you're within the operational range of current and voltage (again, as laid out in the datasheet).



            Wear and tear of an electromechanical relay is usually due to switching under load, i.e. with a voltage applied to the terminals, not being permanently on or off. For more on the issue of contact degradation see here https://en.wikipedia.org/wiki/Relay#Arcing (which I won't make part of this answer as it does not address the question).






            share|improve this answer













            The first stop to answer such questions should be the datasheet of the part in question. This is where the manufacturer lists the operating conditions of the device.



            That aside it is usually safe to have a relay active for longer periods of time, assuming you're within the operational range of current and voltage (again, as laid out in the datasheet).



            Wear and tear of an electromechanical relay is usually due to switching under load, i.e. with a voltage applied to the terminals, not being permanently on or off. For more on the issue of contact degradation see here https://en.wikipedia.org/wiki/Relay#Arcing (which I won't make part of this answer as it does not address the question).







            share|improve this answer












            share|improve this answer



            share|improve this answer










            answered 11 hours ago









            GhanimaGhanima

            12.5k114080




            12.5k114080












            • Thank you so much for your help @Ghanima. Btw does a timer relay also have the same working?

              – Aditya Raghu
              11 hours ago

















            • Thank you so much for your help @Ghanima. Btw does a timer relay also have the same working?

              – Aditya Raghu
              11 hours ago
















            Thank you so much for your help @Ghanima. Btw does a timer relay also have the same working?

            – Aditya Raghu
            11 hours ago





            Thank you so much for your help @Ghanima. Btw does a timer relay also have the same working?

            – Aditya Raghu
            11 hours ago













            1














            To add to @Ghanima's excellent answer, you may also wish to consider a latching relay. Briefly, a latching relay has two stable states (i.e. it is a bistable device, similar to a flip-flop). This means that the relay can be latched into an OPEN or CLOSED state, and it will remain in that state until commanded to change by the input. This avoids the necessity of supplying input voltage and current to maintain (for example) a NORMALLY OPEN relay in a CLOSED state for an extended period of time. Latching relays typically find application in situations similar to the one you've described in your question - where they must be in an OPEN or CLOSED state for extended periods of time.






            share|improve this answer



























              1














              To add to @Ghanima's excellent answer, you may also wish to consider a latching relay. Briefly, a latching relay has two stable states (i.e. it is a bistable device, similar to a flip-flop). This means that the relay can be latched into an OPEN or CLOSED state, and it will remain in that state until commanded to change by the input. This avoids the necessity of supplying input voltage and current to maintain (for example) a NORMALLY OPEN relay in a CLOSED state for an extended period of time. Latching relays typically find application in situations similar to the one you've described in your question - where they must be in an OPEN or CLOSED state for extended periods of time.






              share|improve this answer

























                1












                1








                1







                To add to @Ghanima's excellent answer, you may also wish to consider a latching relay. Briefly, a latching relay has two stable states (i.e. it is a bistable device, similar to a flip-flop). This means that the relay can be latched into an OPEN or CLOSED state, and it will remain in that state until commanded to change by the input. This avoids the necessity of supplying input voltage and current to maintain (for example) a NORMALLY OPEN relay in a CLOSED state for an extended period of time. Latching relays typically find application in situations similar to the one you've described in your question - where they must be in an OPEN or CLOSED state for extended periods of time.






                share|improve this answer













                To add to @Ghanima's excellent answer, you may also wish to consider a latching relay. Briefly, a latching relay has two stable states (i.e. it is a bistable device, similar to a flip-flop). This means that the relay can be latched into an OPEN or CLOSED state, and it will remain in that state until commanded to change by the input. This avoids the necessity of supplying input voltage and current to maintain (for example) a NORMALLY OPEN relay in a CLOSED state for an extended period of time. Latching relays typically find application in situations similar to the one you've described in your question - where they must be in an OPEN or CLOSED state for extended periods of time.







                share|improve this answer












                share|improve this answer



                share|improve this answer










                answered 49 mins ago









                SeamusSeamus

                3,0671322




                3,0671322



























                    draft saved

                    draft discarded
















































                    Thanks for contributing an answer to Raspberry Pi Stack Exchange!


                    • Please be sure to answer the question. Provide details and share your research!

                    But avoid


                    • Asking for help, clarification, or responding to other answers.

                    • Making statements based on opinion; back them up with references or personal experience.

                    To learn more, see our tips on writing great answers.




                    draft saved


                    draft discarded














                    StackExchange.ready(
                    function ()
                    StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fraspberrypi.stackexchange.com%2fquestions%2f96471%2fcan-a-relay-be-on-for-16-hours-continuously%23new-answer', 'question_page');

                    );

                    Post as a guest















                    Required, but never shown





















































                    Required, but never shown














                    Required, but never shown












                    Required, but never shown







                    Required, but never shown

































                    Required, but never shown














                    Required, but never shown












                    Required, but never shown







                    Required, but never shown







                    Popular posts from this blog

                    کانن (شرکت) محتویات تاریخچه[ویرایش] بخشی از تولیدات موفق این شرکت[ویرایش] در رده APS-C[ویرایش] گزارش محیط زیست[ویرایش] رده‌بندی محصولات[ویرایش] منابع[ویرایش] پانویس[ویرایش] پیوند به بیرون[ویرایش] منوی ناوبریwww.canon.comموزه آنلاین دوربین‌های کانننمودار تاریخچه سهام کاننوبگاه رسمی شرکت کاننوووووIDC Worldwide Hardcopy 2013

                    Rest API with Magento using PHP with example. Planned maintenance scheduled April 17/18, 2019 at 00:00UTC (8:00pm US/Eastern) Announcing the arrival of Valued Associate #679: Cesar Manara Unicorn Meta Zoo #1: Why another podcast?How to update product using magento client library for PHP?Oauth Error while extending Magento Rest APINot showing my custom api in wsdl(url) and web service list?Using Magento API(REST) via IXMLHTTPRequest COM ObjectHow to login in Magento website using REST APIREST api call for Guest userMagento API calling using HTML and javascriptUse API rest media management by storeView code (admin)Magento REST API Example ErrorsHow to log all rest api calls in magento2?How to update product using magento client library for PHP?

                    Magento 2 - Auto login with specific URL Planned maintenance scheduled April 23, 2019 at 23:30 UTC (7:30pm US/Eastern) Announcing the arrival of Valued Associate #679: Cesar Manara Unicorn Meta Zoo #1: Why another podcast?Customer can't login - Page refreshes but nothing happensCustom Login page redirectURL to login with redirect URL after completionCustomer login is case sensitiveLogin with phone number or email address - Magento 1.9Magento 2: Set Customer Account Confirmation StatusCustomer auto connect from URLHow to call customer login form in the custom module action magento 2?Change of customer login error message magento2Referrer URL in modal login form